Electric vibrators for hazardous locations Atex compliance – VV E
Available 2,4,6,8 poles up to 9800 Kgf
VV-E VV-E Product Quality Assurance Notification CESI 02 ATEX 112Q Quality Assessment Report IT/CES/QAR20.0004
CERTIFICAZIONI
Compliance with applicable EU Directives.
![]()
II2D II2G (2014/34/UE)
Ex tb IIIC T...°C Db
Ex e IIC T3/T4 Gb
EN 60079-0, EN 60079-7, EN 60079-31
Electric vibrators for gas and dust explosive atmospheres
Cert. N. LCIE07ATEX6032X
![]()
Category: Vibrators for hazardous locations
Description
General Features
Working environment
- 1,2 GAS 21 22 DUST
Power Supply
- Three-phase 230/400V 50Hz. On request three-phase from 42 to 690V 50/60Hz.
- Tropicalization standard on all vibrators.
- Winding insulation with vacuum incapsulating up to GA size included, drop by drop system from HA size
- Insulation class F (155°C).
- Suitable for operation with inverter (VFD) with thermistor from 20Hz up to the rated frequency with constant torque load.
- Thermistor PTC 130°C at request up to size LA, standard from size MA. On request anti – condensation heater.
Functioning
- Working temperature from -20°C a + 40°C (on request +55° C).
- Designed for continuous duty (S1) with 100% centrifugal force CF.
- Standard mechanical protection IP 66.
- 100% components tested.